China ECS-7000MF Fan Energy Saving Controller and Building Equipment Monitoring System - China Supplier China ECS-7000MF Fan Energy Saving Controller and Building Equipment Monitoring System - China Supplier China ECS-7000MF Fan Energy Saving Controller and Building Equipment Monitoring System - China Supplier China ECS-7000MF Fan Energy Saving Controller and Building Equipment Monitoring System - China Supplier

ECS-7000MF Fan Energy Saving Controller and Building Equipment Monitoring System

Price:元999
Industry Category: Electrical-Equipment-Supplies
Product Category:
Brand: 亚川
Spec: ECS-7000MF


Contact Info
  • Add:西安市雁塔区翠华南路60号, Zip:
  • Contact: 张简
  • Tel:15299505139
  • Email:

Other Products

Description
Additional Information

Design Basis for Integrated Building Equipment Monitoring System

GB 50189-2015 "Design Code for Heating, Ventilation and Air Conditioning of Civil Buildings"

JGJ/T229-2010 "Green Design Standard for Civil Buildings"

GB 50736-2012 "Energy Efficiency Design Standard for Public Buildings"

GB 51348-2019 "Standard for Electrical Design of Civil Buildings"

50034-2013 "Standard for Lighting Design of Buildings"

GBT50378-2014 "Assessment Standard for Green Buildings"

GB/T26759-2011 "Technical Specification for Energy-saving Control Devices of Central Air Conditioning Water Systems"

Overview of Integrated Building Equipment Monitoring System:

The integrated building equipment monitoring system uses intelligent devices that integrate power distribution, control, energy saving, energy consumption measurement and analysis, safety alarms, and fieldbus communication to efficiently monitor and manage the building's mechanical and electrical equipment such as air conditioning/fresh air systems, ventilation and exhaust systems, pumps, elevators, and lighting. The building equipment energy-saving controller should be installed in the strong current distribution box of the controlled equipment. The controller should integrate related secondary circuit systems such as relays in the strong current box, using sub-item energy consumption measurement, analysis, energy-saving control strategies, and fieldbus technology to reduce the operating energy consumption of building mechanical and electrical equipment. 3. Air Conditioning/Fresh Air Unit System

Monitor the actual electrical power, supply/return air temperature, CO2 concentration, etc., of the unit.

Automatically adjust the opening of cold/hot water valves and fresh/return air dampers to effectively control the system's fresh/return air ratio, total fresh/return air volume, cold/hot water flow, and fan efficiency under different seasons and operating conditions.

For more product information or product pricing, please call our company.

Product quotation contact number: 15O-O29O-668O

Please contact Manager Zhang: 一五二--O二九O--六六八O (same as VX)

We will wholeheartedly provide you with project drawing design optimization and configuration plan quotations!!!

Equipment Name

ECS-7000 MF Fan Energy-saving Controller

Technical requirements: Dedicated integrated controller for supply and exhaust fans, rail-mounted installation, external energy efficiency monitoring module and three-phase mutual inductor, motor drive device and three-phase integrated mutual inductor, with functions such as intelligent power distribution, intelligent pump control, energy efficiency optimization, and equipment self-inspection. It cooperates with the CPS control and protection switch in the distribution box to provide the distribution box with comprehensive mechatronic integration functions such as phase loss, phase break, overvoltage, undervoltage, overcurrent, undercurrent, short circuit, leakage, and three-phase imbalance protection. The communication interface includes both RS485 and LAN, and can serve as a protocol gateway to integrate and openly access communication devices near the electrical control terminal of the exhaust fan electrical control terminal; the distribution box door is equipped with a high-definition touch screen;

It has an integrated anti-counterfeiting QR code, supporting QR code scanning to monitor the entire lifecycle status of the equipment.

ECS-7000 MB Water Pump Energy-saving Controller

1. Integrated secondary circuit of the chilled water pump electrical control cabinet

2. Manual/remote-automatic control; interlock control; pump group status display; pump group combination configuration and automatic wear balancing function; frequency converter control

3. Real-time tracking and recording of pump group working efficiency

4. Self-inspection function, providing the location and cause of pump group and electrical control box faults for quick maintenance

Other Models

ECS-7000 MF Fan Energy-saving Controller

ECS-7000MKT Air Conditioning/Fresh Air Energy-saving Controller

ECS-7000 MB Water Pump Energy-saving Controller

ECS-7000 MU Universal Energy-saving Controller


Industry Category Electrical-Equipment-Supplies
Product Category
Brand: 亚川
Spec: ECS-7000MF
Stock: 3423
Manufacturer:
Origin: China / Shaanxi / Xianshi